Viresh Kumar f5f263fed6 cpu_cooling: Make of_cpufreq_power_cooling_register() parse DT
All the callers of of_cpufreq_power_cooling_register() have almost
identical code and it makes more sense to move that code into the helper
as its all about reading DT properties.

This got rid of lot of redundant code.

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2017-12-07 22:52:01 +01:00

115 lines
3.3 KiB
C

/*
* linux/include/linux/cpu_cooling.h
*
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
*
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; version 2 of the License.
*
* This program is distributed in the hope that it will be useful, but
* WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* General Public License for more details.
*
* You should have received a copy of the GNU General Public License along
* with this program; if not, write to the Free Software Foundation, Inc.,
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
*
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
*/
#ifndef __CPU_COOLING_H__
#define __CPU_COOLING_H__
#include <linux/of.h>
#include <linux/thermal.h>
#include <linux/cpumask.h>
struct cpufreq_policy;
typedef int (*get_static_t)(cpumask_t *cpumask, int interval,
unsigned long voltage, u32 *power);
#ifdef CONFIG_CPU_THERMAL
/**
* cpufreq_cooling_register - function to create cpufreq cooling device.
* @policy: cpufreq policy.
*/
struct thermal_cooling_device *
cpufreq_cooling_register(struct cpufreq_policy *policy);
struct thermal_cooling_device *
cpufreq_power_cooling_register(struct cpufreq_policy *policy,
u32 capacitance, get_static_t plat_static_func);
/**
* of_cpufreq_cooling_register - create cpufreq cooling device based on DT.
* @np: a valid struct device_node to the cooling device device tree node.
* @policy: cpufreq policy.
*/
#ifdef CONFIG_THERMAL_OF
struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
struct cpufreq_policy *policy);
struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct cpufreq_policy *policy);
#else
static inline struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
struct cpufreq_policy *policy)
{
return ERR_PTR(-ENOSYS);
}
static inline struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct cpufreq_policy *policy)
{
return NULL;
}
#endif
/**
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
* @cdev: thermal cooling device pointer.
*/
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
#else /* !CONFIG_CPU_THERMAL */
static inline struct thermal_cooling_device *
cpufreq_cooling_register(struct cpufreq_policy *policy)
{
return ERR_PTR(-ENOSYS);
}
static inline struct thermal_cooling_device *
cpufreq_power_cooling_register(struct cpufreq_policy *policy,
u32 capacitance, get_static_t plat_static_func)
{
return NULL;
}
static inline struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
struct cpufreq_policy *policy)
{
return ERR_PTR(-ENOSYS);
}
static inline struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct cpufreq_policy *policy)
{
return NULL;
}
static inline
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
{
return;
}
#endif /* CONFIG_CPU_THERMAL */