Uwe Kleine-König e47685ec4c pwm: iqs620a: Fix overflow and optimize calculations
[ Upstream commit 72d6b2459dbd539c1369149e501fdc3dc8ddef16 ]

If state->duty_cycle is 0x100000000000000, the previous calculation of
duty_scale overflows and yields a duty cycle ratio of 0% instead of
100%. Fix this by clamping the requested duty cycle to the maximal
possible duty cycle first. This way it is possible to use a native
integer division instead of a (depending on the architecture) more
expensive 64bit division.

With this change in place duty_scale cannot be bigger than 256 which
allows to simplify the calculation of duty_val.

Fixes: 6f0841a8197b ("pwm: Add support for Azoteq IQS620A PWM generator")
Tested-by: Jeff LaBundy <jeff@labundy.com>
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
2021-03-04 11:38:17 +01:00
..