Florian Fainelli
bfcda65c9b
net: dsa: b53: Fix CPU port for 58xx devices
...
The 58xx devices (Northstar Plus) do actually have their CPU port wired
at port 8, it was unfortunately set to port 5 (B53_CPU_PORT_25) which is
incorrect, since that is the second possible management port.
Fixes: 991a36bb4645 ("net: dsa: b53: Add support for BCM585xx/586xx/88312 integrated switch")
Reported-by: Eric Anholt <eric@anholt.net>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-04-24 18:28:56 -04:00
..
2017-01-09 16:34:39 -05:00
2017-02-27 18:43:47 -08:00
2017-03-04 17:31:39 -08:00
2017-02-27 20:54:04 +02:00
2017-04-04 17:49:59 +02:00
2016-10-31 20:58:34 -04:00
2017-04-24 18:28:56 -04:00
2017-04-24 15:58:03 -04:00
2016-12-29 11:37:14 -05:00
2017-03-22 12:38:17 -07:00
2017-02-22 11:44:32 -08:00
2016-12-24 11:46:01 -08:00
2017-03-16 21:35:33 -07:00
2017-01-12 22:12:43 +01:00
2017-02-11 20:59:41 -05:00
2017-03-25 20:14:40 -07:00
2017-04-20 16:00:48 -04:00
2017-03-02 08:42:32 +01:00
2017-03-02 08:42:29 +01:00
2017-04-06 13:56:49 -07:00
2017-04-21 13:24:06 -04:00
2017-01-30 15:10:42 -05:00
2017-03-13 21:53:48 -07:00
2017-03-13 12:28:40 -07:00
2017-03-30 19:43:51 +03:00
2017-03-12 23:44:43 -07:00
2017-01-24 14:07:22 -05:00
2016-12-24 11:46:01 -08:00
2017-03-01 09:58:31 -08:00
2017-02-27 18:43:47 -08:00
2017-01-08 20:58:52 -05:00
2017-02-17 15:25:49 -05:00
2017-02-11 02:31:11 -05:00
2017-04-24 13:46:58 -04:00
2017-02-11 20:59:41 -05:00
2017-03-02 08:42:32 +01:00
2017-02-11 20:59:41 -05:00
2017-01-02 16:59:10 -05:00
2016-11-09 20:26:58 -05:00
2017-01-08 17:51:44 -05:00
2016-10-20 14:51:09 -04:00
2016-10-20 14:51:10 -04:00
2016-12-24 11:46:01 -08:00
2017-03-03 01:43:37 +01:00
2017-03-21 15:30:59 -07:00
2017-01-08 17:51:44 -05:00
2017-04-07 16:38:59 +03:00
2017-04-17 13:27:54 -04:00
2017-03-13 16:03:42 -07:00
2017-02-22 10:15:09 -08:00