From dc99dfa2ba6661a2f3b02a5c7b710e077761cacf Mon Sep 17 00:00:00 2001 From: Emil Gedenryd Date: Fri, 13 Sep 2024 11:57:02 +0200 Subject: [PATCH] iio: light: opt3001: add missing full-scale range value commit 530688e39c644543b71bdd9cb45fdfb458a28eaa upstream. The opt3001 driver uses predetermined full-scale range values to determine what exponent to use for event trigger threshold values. The problem is that one of the values specified in the datasheet is missing from the implementation. This causes larger values to be scaled down to an incorrect exponent, effectively reducing the maximum settable threshold value by a factor of 2. Add missing full-scale range array value. Fixes: 94a9b7b1809f ("iio: light: add support for TI's opt3001 light sensor") Signed-off-by: Emil Gedenryd Cc: Link: https://patch.msgid.link/20240913-add_opt3002-v2-1-69e04f840360@axis.com Signed-off-by: Jonathan Cameron Signed-off-by: Greg Kroah-Hartman --- drivers/iio/light/opt3001.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/drivers/iio/light/opt3001.c b/drivers/iio/light/opt3001.c index ff776259734a..ff01fc9fc0b2 100644 --- a/drivers/iio/light/opt3001.c +++ b/drivers/iio/light/opt3001.c @@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = { .val = 20966, .val2 = 400000, }, + { + .val = 41932, + .val2 = 800000, + }, { .val = 83865, .val2 = 600000,