Don't abort clock initialization if we cannot match an entry in
tegra_clk_init_table to a valid entry in the clk array.
Also log a corresponding error message.
This was discovered when testing a patch that removed the EMC clock from
tegra124_clks but left a mention in tegra_clk_init_table.
Signed-off-by: Tomeu Vizoso <tomeu.vizoso@collabora.com>
Reviewed-by: Stephen Warren <swarren@nvidia.com>